A soft, flexible sensor system created with electrically conductive yarns could help map problematic pressure points in the socket of an amputee’s prosthetic limb, researchers from North Carolina State University report, in IEEE Sensors Journal.

According to the researchers, the lightweight, soft textile-based sensor prototype patch incorporates a lattice of conductive yarns and is connected to a tiny computer. They tested the system on a prosthetic limb and in walking experiments with two human volunteers, finding the system could reliably track pressure changes in real time, a media release from North Carolina State University notes.

“What people commonly use to measure pressure within prosthetics are rigid sensors. They’re hard, they’re bulky; they can be heavy. These are not things that amputees can use on a daily basis because rigid sensors negatively affect the fit of amputees’ prosthetics. Rigid sensors can also cause discomfort. We designed sensors that can be integrated into textiles in a way that doesn’t cause any additional discomfort for the user, and could be worn on a more regular basis.”

— the study’s first author Jordan Tabor, a graduate student in the NC State College of Textiles

In one experiment, the researchers tested whether the patch could detect changes in pressure when they placed it on an artificial limb, turned at different angles. Then they used it to test pressure changes when an able-bodied person wore the sensor patch while walking with a bent-knee adaptor and while shifting their weight between legs.

In their last experiment, a volunteer with an amputated lower leg wore the patch on the liner of their prosthetic limb in areas where the prosthetic typically applies higher pressure. They tested the sensor patch while the volunteer shifted weight and walked on a treadmill, finding the system was durable and could reliably monitor pressure changes in the socket.

“This approach that we thought of a few years ago does work, and it’s a readily manufacturable technology. You cannot put materials next to the skin that are uncomfortable and may not be safe. So we are putting things that are used around us all the time, and are soft and flexible.”

— Tushar Ghosh, the study’s co-corresponding author and the William A. Klopman Distinguished Professor of Textile Engineering, Chemistry & Science in NC State’s Wilson College of Textiles.

Lightweight and Small

Part of the researchers’ work involved designing the sensor system to be lightweight and small enough for human use. The work was a collaboration between researchers in textile, electrical, computer and biomedical engineering at NC State. The human experiments were performed by rehabilitation engineering researchers led by Helen Huang, the Jackson Family Distinguished Professor in the UNC/NC State Joint Department of Biomedical Engineering and a senior co-author of the paper.

They created the sensor patch by sewing the yarns together in such a way that they created an electromagnetic field. When the researchers sewed the yarns into a lattice, and applied a small amount of electrical power using a small battery, they found they could measure the amount of electrical charge drawing the yarns together at each lattice point. The charges change depending on how close the yarns are together, which is related to how much pressure is applied by the wearer. They connected yarns, insulated them, laid them on a textile fabric, and connected them to a small electronic device to capture the data. They also included a small radio in order to wirelessly track the measurements.

“We connected the textile fibers to an electrical circuit that is a little larger than a quarter, and that can scan as many as 10 by 10 fibers. That gives us 100 points of measurement. Everything is connected to a tiny microcomputer, which has a radio for wireless data tracking.”

— co-corresponding author Alper Bozkurt, professor of electrical engineering at NC State

While researchers used a yarn that was commercially available for the study, they are also working on developing their own textile fiber to detect more than just pressure changes in the socket of an amputee’s prosthetic limb.

The next step in the project is to integrate the sensors into prosthetic sockets directly, or into a wearable item. They would also need to study the sensor’s potential clinical value in a larger study.

“Our broader vision is to design something like a sock, or to integrate the sensor system into the prosthetic socket, so when a person dons their prosthesis, they are able to monitor what’s happening in terms of pressure distribution and other measurements.”

— Helen Huang

[Source(s): North Carolina State University, Science Daily]


Related Content:
BCBS to Quadruple Amputee: No wheelchair. You can walk a little
Amputees Report Ability to Merge with Their Bionic Leg
For Amputees, Staying Physically Active Can Be Challenging